Waterford Precision Cycles Ventilation Hood Glass Island Hood User Manual |
An AGA Company
GLASS ISLAND HOOD - 90 CM
To be installed by a trained and competent person
INSTALLATION & OPERATING MANUAL
To be left with end user
GENERAL GUIDELINES
MAINTENANCE
Before installing and /or using the cooker hood,
please read these instructions carefully.
Before servicing or repairing the hood make sure the
appliance is disconnected from the mains supply
either by removing the plug or switching the power
socket to OFF.
Before installing the cooker hood make sure the volt-
age (V), frequency (Hz) indicated on the serial num-
ber plate and specifications on the rating plate on the
inside of the cooker hood correspond to the voltage
and frequency of the mains supply.
CLEANING
Clean the outer part of the hood with a soft cloth and
liquid detergent, do not use abrasive cleaning prod-
ucts or scouring pads.
INSTALLATION
The cooker hood must not be installed and connect-
ed to flues where other appliances are installed and
which run off other energy supplies other than elec-
tricity (water heaters - boilers - cookers, range/gas
etc). The extraction hood requires a 125mm extrac-
tion pipe connected directly to the outside with an
opening of a minimum cross section of 150cm2.
It is recommended to wash the filters in a dishwash-
er or in water up to 60oC every 3 months.
CHANGING THE LIGHT BULB
Before changing the light bulb, ensure that the appli-
ance is not live (the switch should be in position 0 -
OFF). Remove the metal anti-grease filters (Fig.5).
Change the halogen light using a 230V halogen light,
with an E14 coupling, max. 50W. Replace the metal
anti-grease filters.
The hood must be installed with a distance of 650-
750mm between the cooker top/hob and the extrac-
tion hood. The cooker hood must not be installed
above cookers with eye-level grills.
ELECTRICAL CONNECTION
WARNINGS
This cooker hood is designed for permanent fixture.
Connect to mains supply. Check voltage and fre-
quency given on the rating plate located on the
inside of the hood. Connect the mains cable to a
power socket or to a double pole switch with a con-
tact gap of at least 3mm. The mains cable (type
H05VV- F 2x 0.75 mm2) is connected to terminals
marked with the letters L (power line) and N (neutral)
mounted on the hood and is secured in position by a
cable gland. The mains cable must be connected to
a suitable and easily accessible fixed power point.
As the electrical installation must comply with the
laws and regulations in force only a qualified and
authorised electrician must install the hood including
connecting it to a double pole switch with a contact
gap of at least 3mm.
“NOTE: the areas behind the filters are not
intended to be cleaned”
Follow the cleaning instructions given by the manu-
facturer and in particular take care that there are not
grease deposits on the surface of the hood which
could create a possible fire hazard. Make sure the
electric hob rings or gas rings are always covered
when in use to avoid heating the filter.
When frying never leave pans unattended as there is
the risk of the oil overheating and catching fire. If
reusing frying oil the fire risk is greater. Never pre-
pare flame cooked food dishes under the hood. The
air duct by the hood must not be conveyed into a flue
used for other appliances that run off other energy
supplies other than electricity. If the air is to be duct-
ed, before installing make sure the flue is in good
condition especially if it has been out of use for a
long period of time. Always observe governing laws
and regulations regarding ducting waste gases. All
rec- ommendations given must be scrupulously
observed to avoid any possible fire hazard.
Connect the mains cable if provided with a plug to a
power socket. The user must have access to the
power socket to be able to connect and disconnect
the plug once the hood is mounted and fixed.
The manufacturer will not be responsible if the gov-
erning health and safety laws are not observed
which permit safe and correct use of the hood and
electrical connections.
2
To delete this prompt, once the filters have been
cleaned and with the cooker hood off (not powered),
maintain push-button 2 pressed for more than 5 sec-
onds. When you press this push-button the letter “A”
will come up on the display and then disappear after
5 seconds. The microprocessor zeros the number of
hours and starts a new count from zero until reach-
ing 30 hours prompting this maintenance procedure.
CONTROL PANEL
The control panel is situated on the front of the hood
and comprises of a digital display and 5 touch con-
trol switches with the following functions: (See Fig.9)
Fan ON/OFF Switch
Reduces the speed of the fan (Min
speed 1)
VENTILATION
Digital display,displays the speed of
the fan 1-6
If there is an appliance fitted in the vicinity which
requires air for combustion, additional air vents will
be required to alleviate the possibility of spillage of
products of combustion, from the appliance/flue
while the fan is in operation. Refer to B.S. 5440 Part
2 & I.S. 813.
Increases the speed of the fan (Max
speed 6)
OFF delay switch, press once display
flashes, fan switches off automatically
after 15 minutes
Where such an installation exists a test for spillage
should be carried out with all appliances requiring air
for combustion and all extraction fans running at
maximum rate, (i.e. tumble dryers, extraction fans)
with all external windows and doors closed.
Light ON/OFF switch
SPECIFICATIONS
If spillage occurs following the above operation, an
additional air vent of sufficient size to prevent this
occurrence should be installed.
The electronic controls on your ducting cooker hood
have multiple functions-features:
FITTING INSTRUCTIONS
Motor on-off Function
The motor is turned on and off by pressing push-but-
ton no.1. When you turn on the cooker hood it auto-
matically starts running at the third speed.
1. Fix the ceiling bracket to the ceiling, making sure
that the riveted brackets for fixing the stainless
steel casing are to the side. Adjust the chimney
section to the required length. See Fig. 2 & 2a.
Timer Function
This function permits you to program your cooker
hood so that the motor and lights turn off automati-
cally 15 minutes after you have activated this func-
tion. To program press push-button no.4. At the bot-
tom on the right of the display a point will flash indi-
cating that the timer function is activated.
2. Slide the stainless casing over the chimney
section keeping vents to the side. See Fig.3.
3. Mount the chimney section on the ceiling bracket,
note tabs must fit into the slots on the ceiling
bracket to hold this section in place while fitting
the fixing screws. See Fig.4.
Lights on-off Function
To turn the lights on and off press push-button no. 5.
4. Fit 4 fixing screws one in each corner. See
Fig. 5. Fit the glass onto the hood section using
clamps provided (See Fig 6). Connect the plug
and socket between the chimney and the hood
section.
Specific Features
The electronic controls provided on your ducting
cooker hood have advanced features to facilitate
maintenance and correct utilisation.
5. Lift the glass section into place, the clip on either
side will hold hood in place while fitting the fixing
screws. See Fig 7.
Prompt-Clean Metal Filters
After every 30 hours of use a microprocessor,
prompts the user that it is time to clean the metal
grease filters to guarantee better ducting perform-
ance and to improve hygiene. This prompt is indicat-
ed by the letter “A” which flashes on the display.
3
THE MANUFACTURER WILL NOT BE RESPONSIBLE IF THESE RECOMMENDATIONS AND INSTRUC-
TIONS REGARDING INSTALLATION, MAINTENANCE AND USE ARE NOT OBSERVED AND RESPECTED
WHEN USING THE COOKER HOOD.
Fig.3
Fig.1
Fig.2
Riveted
Brackets
Vents
Fig.2a
4
Fig.4
Fig.6
Fig.5
Clips to hold
glass in place
Hood Glass
5
Fig.7
DIMENSIONS
6
An AGA Company
WARRANTY
We undertake to repair or replace, free of charge to you any part found to be faulty within the
12 month period from the date of purchase provided that:-
*
*
*
*
The fault is, in our opinion, caused by defective workmanship, or material and not by accident,
misuse, neglect or normal wear and tear.
Any manufacturing defect is reported to the stockist from whom you bought the appliance
within 12 months of the date of purchase.
The Waterford appliance is installed to the Manufacturer’s recommendations and by a suitably
qualified person.
The guarantee registration form is completed fully and returned to us within 30 days of the
purchase date.
IMPORTANT NOTICE: Any alteration to this appliance that is not approved in writing by Waterford Stanley
will render the guarantee void.
Waterford Stanley Ltd.,
Unit 210, IDA Industrial Estate, Cork Road,
Waterford, Ireland.
Tel: (051) 302300 Fax (051) 302315
Rev: 001 DP 080212
7
|
Technicolor Thomson Computer Drive TG122N User Manual
Texas Instruments Digital Camera MC 1000WU 20A User Manual
Toshiba Computer Drive MG03ACA300 User Manual
Toshiba Cordless Telephone FT 8981 User Manual
Toshiba DVD Player E 2 15 ESE R User Manual
Tripp Lite TV Cables P106 06I User Manual
ViewSonic Projector VS12996 User Manual
Vivitek Projector D735VX User Manual
Vizio TV Video Accessories XCH508 User Manual
Weber Gas Grill 30793 User Manual